Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Age Ageing ; 51(11)2022 Nov 02.
Article in English | MEDLINE | ID: covidwho-2314430

ABSTRACT

More than one-third of the cases of infective endocarditis (IE) occur in older patients. The disease is often characterized by atypical symptoms. The incidence of neurological complications is high and represents a strong independent predictor of severe outcomes and mortality. IE is a rare but serious complication of transcatheter aortic valve implantation (TAVI). A persistent delirium as a unique manifestation of post-TAVI IE in an older patient is presented in this clinical case.


Subject(s)
Aortic Valve Stenosis , Delirium , Endocarditis, Bacterial , Endocarditis , Prosthesis-Related Infections , Transcatheter Aortic Valve Replacement , Humans , Aged , Transcatheter Aortic Valve Replacement/adverse effects , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Endocarditis/etiology , Endocarditis/complications , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/etiology , Delirium/etiology , Delirium/complications , Aortic Valve Stenosis/surgery , Aortic Valve , Treatment Outcome , Risk Factors
2.
BMC Cardiovasc Disord ; 23(1): 187, 2023 04 06.
Article in English | MEDLINE | ID: covidwho-2262605

ABSTRACT

BACKGROUND: COVID-19 has caused the deferral of millions of elective procedures, likely resulting in a backlog of cases. We estimate the number of postponed surgical aortic valve replacement (sAVR) and transcatheter aortic valve replacement (TAVR) procedures during the first two waves of the COVID-19 pandemic in Germany. METHODS: Using German national records, all isolated TAVR and sAVR procedures between 2007 and 2020 were identified. Using weekly TAVR and sAVR procedures between 2017 and 2019, we created a forecast for 2020 and compared it with the observed number of procedures in 2020. RESULTS: In Germany, a total of 225,398 isolated sAVR and 159,638 isolated TAVR procedures were conducted between 2007 and 2020 that were included in our analysis. The reduction in all AVR procedures (sAVR and TAVR) for the entire year 2020 was 19.07% (95%CI: 15.19-22.95%). During the first wave of the pandemic (week 12-21), the mean weekly reduction was 32.06% (23.44-40.68%) and during the second wave of the pandemic (week 41-52), the mean weekly reduction was 25.58% (14.19-36.97%). The number of sAVR procedures decreased more than the number of TAVR procedures (24.63% vs. 16.42% for the entire year 2020). CONCLUSION: The first year of the COVID-19 pandemic saw a substantial postponing of AVR procedures in Germany. Postponing was higher for sAVR than for TAVR procedures and less pronounced during the second wave of the COVID-19 pandemic.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Pandemics , Aortic Valve Stenosis/surgery , Risk Factors , Treatment Outcome , Hospital Mortality , COVID-19/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Germany/epidemiology
3.
Medicina (Kaunas) ; 59(1)2022 Dec 21.
Article in English | MEDLINE | ID: covidwho-2231255

ABSTRACT

Background and objectives: One of the leading causes of mortality and morbidity in people over the age of 50 is stroke. The acceptance of transcatheter aortic valve replacement (TAVR) as a treatment option for severe symptomatic aortic stenosis (AS) has increased as a result of numerous randomized clinical trials comparing surgical aortic valve replacement (SAVR) and TAVR in high- and intermediate-risk patients, showing comparable clinical outcomes and valve hemodynamics. Materials and Methods: An electronic search of Medline, Google Scholar and Cochrane Central was carried out from their inception to 28 September 2022 without any language restrictions. Results: Our meta-analysis demonstrated that, as compared with SAVR, TAVR was not linked with a lower stroke ratio or stroke mortality. It is clear from this that the SAVR intervention techniques applied in the six studies were successful in reducing cardiogenic consequences over time. Conclusions: A significantly decreased rate of mortality from cardiogenic causes was associated with SAVR. Additionally, when TAVR and SAVR were compared for stroke mortality, the results were nonsignificant with a p value of 0.57, indicating that none of these procedures could decrease stroke-related mortality.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Myocardial Infarction , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Pandemics , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/surgery , Risk Factors , COVID-19/complications , Stroke/etiology , Myocardial Infarction/complications , Treatment Outcome
4.
Rev Med Chil ; 150(2): 183-189, 2022 Feb.
Article in Spanish | MEDLINE | ID: covidwho-2055638

ABSTRACT

COVID-19 pandemic generated multiple challenges for the health system. Cardiovascular disease is associated with a worse prognosis of infections. Moreover, most hospital resources and operative rooms were destined to patients with COVID-19 infection, deferring the treatment of most valvular patients requiring surgery. We report seven patients with symptomatic severe aortic stenosis who underwent transcatheter aortic valve implantation (TAVI) with conscious sedation and early discharge. No patient required intensive care unit admission or mechanical ventilation. After a 90-day follow-up, there were no complications or unplanned readmissions.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Conscious Sedation/adverse effects , Humans , Pandemics , Patient Discharge , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
5.
Aging Clin Exp Res ; 34(8): 1873-1883, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-1995921

ABSTRACT

AIM: We estimated the proportion and severity of cognitive disorders in an unselected population of patients referred for transcatheter aortic valve implantation (TAVI). Second, we describe clinical and cognitive outcomes at 1 year. METHODS: Eligible patients were aged ≥ 70 years, with symptomatic aortic stenosis and an indication for TAVI. The Montreal Cognitive Assessment (MoCA) was used to assess cognitive dysfunction (CD), defined as no CD if score ≥ 26, mild CD if 18-25; moderate CD if 10-18, and severe CD if < 10. We assessed survival and in-hospital complications at 6 months and 1 year. RESULTS: Between June 2019 and October 2020, 105 patients were included; 21 (20%) did not undergo TAVI, and thus, 84 were analyzed; median age 85 years, 53.6% females, median EuroScore 11.5%. Median MoCA score was 22 (19-25); CD was excluded in 18 (21%), mild in 50 (59.5%), moderate in 15 (19%) and severe in 1. Mean MoCA score at follow-up was 21.9(± 4.69) and did not differ significantly from baseline (21.79 (± 4.61), p = 0.73). There was no difference in success rate, in-hospital complications, or death across CD categories. CONCLUSION: The clinical course of patients with mild or moderate CD is not different at 1 year after TAVI compared to those without cognitive dysfunction.


Subject(s)
Aortic Valve Stenosis , Cognitive Dysfunction , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Cognition , Cognitive Dysfunction/epidemiology , Cognitive Dysfunction/etiology , Female , Humans , Male , Prevalence , Risk Assessment , Risk Factors , Severity of Illness Index , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
8.
Am J Cardiol ; 176: 105-111, 2022 08 01.
Article in English | MEDLINE | ID: covidwho-1866798

ABSTRACT

New-onset left bundle branch block (NLBBB) is the most common complication after transcatheter aortic valve implantation (TAVI). Expert consensus recommends temporary transvenous pacemaker (TTVP) support for 24 hours in these patients. To date, no study has examined TTVP use during the index hospitalization in detail. Therefore, we aimed to assess TTVP use in patients with TAVI who developed NLBBB. In this prospective observational study, we performed a detailed analysis of 24-hour telemetry in patients who developed NLBBB during TAVI. Baseline characteristics and procedural and postprocedural data were recorded. The primary outcome was pacing by the TTVP. We evaluated inappropriate TTVP use, electrophysiology study findings, permanent pacemaker (PPM) implantation, and NLBBB resolution. A total of 83 patients (74.4 ± 8.7 years, 41% female) developed NLBBB during TAVI. During index hospitalization, 1 patient (1%) required TTVP because of complete heart block and received a PPM. Five of the 83 (6%) patients were inappropriately paced, and 1 patient (1%) had ventricular fibrillation, likely secondary to TTVP. A total of 34 patients (41%) underwent electrophysiology study during hospitalization, with 4 of 83 (5%) subsequently receiving a PPM. One (1%) patient died during hospitalization, and 9 patients were lost to follow-up because of the COVID-19 pandemic. Of the remaining 73 patients with a 30-day follow-up, NLBBB had resolved in 36 (49%) at 30 days, and 2 (3%) were readmitted with complete heart block and received PPM. In conclusion, in patients with TAVI who develop NLBBB, temporary pacing is rarely necessary, may carry additional risks to the patient, and prolong hospitalization time.


Subject(s)
Aortic Valve Stenosis , Atrioventricular Block , COVID-19 , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Arrhythmias, Cardiac/therapy , Atrioventricular Block/etiology , Bundle-Branch Block/epidemiology , Bundle-Branch Block/etiology , Bundle-Branch Block/therapy , COVID-19/epidemiology , Cardiac Pacing, Artificial/adverse effects , Female , Humans , Male , Pacemaker, Artificial/adverse effects , Pandemics , Postoperative Complications/epidemiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
JACC Cardiovasc Interv ; 15(6): 590-598, 2022 03 28.
Article in English | MEDLINE | ID: covidwho-1747832

ABSTRACT

OBJECTIVES: The aim of this study was to determine the safety and efficacy of same-day discharge (SDD) after transcatheter aortic valve replacement (TAVR) during the COVID-19 pandemic. BACKGROUND: The COVID-19 pandemic has placed significant stress on health care systems worldwide. SDD in highly selected TAVR patients can facilitate the provision of essential cardiovascular care while managing competing COVID-19 resource demands. METHODS: Patient selection for SDD was at the discretion of the local multidisciplinary heart team, across 7 international sites. The primary outcome was a composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new permanent pacemaker (PPM) implantation. RESULTS: From March 2020 to August 2021, 124 of 2,100 patients who underwent elective transfemoral TAVR were selected for SDD. The average age was 78.9 ± 7.8 years, the median Society of Thoracic Surgeons score was 2.4 (IQR: 1.4-4.2), and 32.3% (n = 40) had preexisting PPMs. There were no major vascular complications, strokes, or deaths during the index admission. One patient (0.8%) required PPM implantation for complete heart block and was discharged the same day. No patient required a PPM between discharge home and 30-day follow-up. The composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new PPM at 30 days occurred in 5.7% patients (n = 6 of 106). CONCLUSIONS: SDD post-TAVR is safe and feasible in selected patients at low risk for adverse clinical events postdischarge. This strategy may have a potential role in highly selected patients even when the COVID-19 pandemic abates.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Aftercare , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Pandemics , Patient Discharge , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
10.
Catheter Cardiovasc Interv ; 99(6): 1789-1795, 2022 05.
Article in English | MEDLINE | ID: covidwho-1653183

ABSTRACT

Despite advances in transcatheter aortic valve replacement (TAVR) technology, periprocedural stroke remains a complication of TAVR procedures. The TriGUARD 3 device is designed to be positioned in the aortic arch to deflect debris away from the brachiocephalic, left common carotid, and left subclavian arteries during TAVR. The United States Food and Drug Administration (FDA) assembled the Circulatory System Devices Panel to review safety and effectiveness data for the TriGUARD 3 device. Because of the coronavirus disease 2019 pandemic, this meeting was held virtually. In this manuscript, we summarize the data presented by both the sponsor and FDA, as well as the panel discussion.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Embolic Protection Devices , Intracranial Embolism , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Humans , Intracranial Embolism/etiology , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , United States , United States Food and Drug Administration
12.
PLoS One ; 16(10): e0258963, 2021.
Article in English | MEDLINE | ID: covidwho-1496521

ABSTRACT

OBJECTIVE: Transcatheter aortic valve implantation (TAVI) provokes early injury response, represented in part by dynamic changes in the inflammatory markers. The association of self-expanding valves (SEVs) and balloon-expandable valves (BEVs) with the consequent inflammatory response remains uncertain. MATERIALS AND METHODS: Patients with severe symptomatic aortic stenosis who underwent transfemoral TAVI: SEVs or BEVs, from January 2010 to December 2019 were enrolled. Whole white blood cells (WBC) and subpopulation dynamics as well the neutrophil to lymphocyte ratio (NLR) were evaluated. RESULTS: Three-hundred seventy consecutive patients (mean age 81.75 ± 6.8 years, 199 women's) were enrolled. In the entire population, significant kinetic changes in the WBC response (p <0.0001) between admission and first 24 hours post procedure, with a significant increase in total WBC (7.46 ± 2.26 to 10.08 ± 3.55) and absolute neutrophil count (4.97 ± 2.06 to 8.19 ± 3.43), NL ratio (3.72 ± 2.8 to 9.76 ± 7.29), and a meaningful decrease in absolute lymphocytes count (1.67 ± 1.1 to 1.1 ± 0.76). When compared between the types of valves, SEVs were associated with a more pronounced inflammatory response than BEVs, with total WBC (10.44 ± 3.86 vs. 9.45 ± 3.19) neutrophils (8.56 ± 3.75 vs. 7.55 ± 3.06) with p 0.016 and 0.012 respectively. CONCLUSION: This is the first description of a differential inflammatory response between the two leading delivery systems. SEV appears to trigger a more robust inflammatory response as compared to BEV. Clinical studies are warranted to assess the long term effect of our findings.


Subject(s)
Aortic Valve Stenosis/surgery , Heart Valve Prosthesis , Inflammation/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Aged , Aged, 80 and over , Aortic Valve Stenosis/blood , Female , Humans , Inflammation/blood , Lymphocytes , Male , Neutrophils , Postoperative Complications/blood , Postoperative Complications/etiology , Treatment Outcome
13.
Clin Cardiol ; 44(10): 1344-1353, 2021 Oct.
Article in English | MEDLINE | ID: covidwho-1453560

ABSTRACT

BACKGROUND: The use of transcatheter aortic valve implantation (TAVI) for treating aortic stenosis (AS) has increased exponentially in recent years. Despite the availability of clinical practice guidelines for the management of valvular heart disease, disparities in quality of care (QoC) for TAVI patients remain widespread across Europe. Tailored QoC measures will help to reduce resource utilization and improve patient outcomes without compromising patient safety. Using a clear set of QoC measures, the BENCHMARK registry aims to document the progress that can be achieved if such tailored QoC measures are implemented. METHODS: The BENCHMARK registry (BENCHMARK) is a non-interventional, multicenter registry in patients with severe symptomatic AS undergoing TAVI with a 1- and 12-months follow-up. BENCHMARK will be conducted at 30 centers across Europe and will enroll a total of 2400 consecutive TAVI patients. Patients suffering from severe symptomatic AS who undergo TAVI with a balloon-expandable transcatheter aortic valve will be included. The registry will comprise four phases: (1) a retrospective baseline evaluation phase; (2) an education phase; (3) an implementation phase; and (4) a prospective effect documentation phase (prospective phase). The registry's primary objectives are to reduce the length of hospital stay and accelerate the post-procedural patient recovery pathway, but without compromising safety. The study started in April 2021 and has an estimated completion date of May 2023. DISCUSSION: BENCHMARK will establish QoC measures to reduce resource utilization, intensive care unit bed occupancy, and overall length of hospitalization with uncompromised patient safety post-TAVI (ClinicalTrials.gov Identifier: NCT04579445).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Benchmarking , Europe , Humans , Prospective Studies , Registries , Retrospective Studies , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
14.
Cardiovasc Revasc Med ; 28S: 68-71, 2021 07.
Article in English | MEDLINE | ID: covidwho-1176553

ABSTRACT

In 2020, the coronavirus disease 2019 (COVID-19) pandemic has led to a decrease in interventional treatment for structural heart disease worldwide. In this context, the management of patients with symptomatic severe aortic stenosis (AS) or bioprosthetic valve dysfunction (BVD) represents a clinical challenge, as a delay in aortic valve replacement procedures may increase short-term morbidity and mortality. We report four cases of TAVR performed in patients with Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) infection. All of them were discharged in good clinical conditions and no adverse events were reported at 30 days follow-up. Our experience suggests that in selected patients with mild SARS-CoV-2 infection and symptomatic native AS or BVD, TAVR has a favorable short-term outcome.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Feasibility Studies , Humans , Risk Factors , SARS-CoV-2 , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
15.
Catheter Cardiovasc Interv ; 98(3): E478-E482, 2021 09.
Article in English | MEDLINE | ID: covidwho-1074302

ABSTRACT

The COVID-19 pandemic has resulted in the cancellation of many elective surgical procedures. This has led to reports of an increase in mortality for patients with non-Covid health conditions due to delayed definitive management. Patients with severe aortic stenosis have a high annual mortality if left untreated. These patients are at risk due to the reduced number of surgical aortic valve replacements and competition for intensive care facilities during the COVID-19 pandemic. This case series suggests that the minimally invasive transcatheter aortic valve implantation is safe to continue during the COVID-19 pandemic with adjustments to the patient pathway to minimize hospital stay and to reduce patient and staff exposure. This helps to reduce the delay of definitive treatment for patients with severe aortic stenosis.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/adverse effects , Humans , Pandemics , Risk Factors , SARS-CoV-2 , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
16.
Catheter Cardiovasc Interv ; 98(5): E733-E736, 2021 11 01.
Article in English | MEDLINE | ID: covidwho-1059412

ABSTRACT

OBJECTIVES: The current report describes a single operator's experience of the first use of smartglass technology as a facilitator of virtual support during TAVR proctoring. BACKGROUND: Restricted gatherings and containment measures during the ongoing COVID-19 pandemic have a major impact on daily clinical practice. Interaction between peers is crucial in science, clinical practice, and education. In addition, there is also a growing importance of proctoring in interventional cardiology for structural heart disease. Virtual support may facilitate the wide implementation of remote proctoring. METHODS: A collaboration between a smartglass provider (Rods & Cones) and self-expandable transcatheter aortic heart valve system (Medtronic) was initiated and tested extensively prior to TAVR procedures. Two cases were randomly selected for remote support. The light-weight smartglass consisted of a full HD central camera, a 720p ×5 optical zoom camera, built-in LED light, speaker and earphone jack, and an external visor to project data in a nonobstructive manner in the operators' view. RESULTS: Preprocedural detailed discussion of the cases between the proctor and the operator occurred via teleconferencing. Successful procedural virtual support was determined by the presence of a session coordinator, high quality of the central camera, high-speed and stable wireless internet connection. Limitations were the relative discomfort of the earpieces, discordance between the central and zoom camera and the absence of visual fixation during head motions. CONCLUSION: In a highly complex and demanding context such as TAVR, remote proctoring by means of virtual support is feasible and efficacious.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Pandemics , Risk Factors , SARS-CoV-2 , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
17.
Cardiovasc Revasc Med ; 31: 26-31, 2021 10.
Article in English | MEDLINE | ID: covidwho-956955

ABSTRACT

BACKGROUND: The risk of nosocomial COVID-19 infection for vulnerable aortic stenosis patients and intensive care resource utilization has led to cardiac surgery deferral. Untreated severe symptomatic aortic stenosis has a dismal prognosis. TAVR offers an attractive alternative to surgery as it is not reliant on intensive care resources. We set out to explore the safety and operational efficiency of restructuring a TAVR service and redeploying it to a new non-surgical site during the COVID-19 pandemic. METHODS: The institutional prospective service database was retrospectively interrogated for the first 50 consecutive elective TAVR cases prior to and after our institution's operational adaptations for the COVID-19 pandemic. Our endpoints were VARC-2 defined procedural complications, 30-day mortality or re-admission and service efficiency metrics. RESULTS: The profile of patients undergoing TAVR during the pandemic was similar to patients undergoing TAVR prior to the pandemic with the exception of a lower mean age (79 vs 82 years, p < 0.01) and median EuroScore II (3.1% vs 4.6%, p = 0.01). The service restructuring and redeployment contributed to the pandemic-mandated operational efficiency with a reduction in the distribution of pre-admission hospital visits (3 vs 3 visits, p < 0.001) and the time taken from TAVR clinic to procedure (26 vs 77 days, p < 0.0001) when compared to the pre-COVID-19 service. No statistically significant difference was noted in peri-procedural complications and 30-day outcomes, while post-operative length of stay was significantly reduced (2 vs 3 days, p < 0.0001) when compared to pre-COVID-19 practice. CONCLUSIONS: TAVR service restructuring and redeployment to align with pandemic-mandated healthcare resource rationalization is safe and feasible.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/epidemiology , Aortic Valve Stenosis/surgery , Humans , Pandemics , Prospective Studies , Retrospective Studies , Risk Factors , SARS-CoV-2 , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
Ann Thorac Surg ; 111(2): 701-722, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-935431

ABSTRACT

The STS-ACC TVT Registry (Society of Thoracic Surgeons-American College of Cardiology Transcatheter Valve Therapy Registry) from 2011 to 2019 has collected data on 276,316 patients undergoing transcatheter aortic valve replacement (TAVR) at sites in all U.S. states. Volumes have increased every year, exceeding surgical aortic valve replacement in 2019 (72,991 vs. 57,626), and it is now performed in all U.S. states. TAVR now extends from extreme- to low-risk patients. This is the first presentation on 8,395 low-risk patients treated in 2019. In 2019, for the entire cohort, femoral access increased to 95.3%, hospital stay was 2 days, and 90.3% were discharged home. Since 2011, the 30-day mortality rate has decreased (7.2% to 2.5%), stroke has started to decrease (2.75% to 2.3%), but pacemaker need is unchanged (10.9% to 10.8%). Alive with acceptable patient-reported outcomes is achieved in 8 of 10 patients at 1 year. The Registry is a national resource to improve care and analyze TAVR's evolution. Real-world outcomes, site performance, and the impact of coronavirus disease 2019 will be subsequently studied. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528).


Subject(s)
Registries , Transcatheter Aortic Valve Replacement/statistics & numerical data , Aged , Aged, 80 and over , Cardiopulmonary Bypass , Female , Health Status , Humans , Length of Stay , Male , Pacemaker, Artificial , Stroke/epidemiology , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , United States/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL